Metrics
Affected Vendors & Products
No advisories yet.
Solution
The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API.
Workaround
No workaround given by the vendor.
Wed, 03 Dec 2025 19:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Circutor
Circutor sge-plc1000 Circutor sge-plc1000 Firmware Circutor sge-plc50 Circutor sge-plc50 Firmware |
|
| CPEs | cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:* cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:* cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:* cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:* |
|
| Vendors & Products |
Circutor
Circutor sge-plc1000 Circutor sge-plc1000 Firmware Circutor sge-plc50 Circutor sge-plc50 Firmware |
|
| Metrics |
cvssV3_1
|
Tue, 02 Dec 2025 15:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
Tue, 02 Dec 2025 13:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “sprintf()” to format a string that includes the user-controlled input of 'GetParameter(meter)' in the fixed-size buffer 'acStack_4c' (64 bytes) without checking the length. An attacker can provide an excessively long value for the 'meter' parameter that exceeds the 64-byte buffer size. | |
| Title | Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 | |
| First Time appeared |
Sge-plc1000 Sge-plc50
Sge-plc1000 Sge-plc50 circutor |
|
| Weaknesses | CWE-121 | |
| CPEs | cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:* | |
| Vendors & Products |
Sge-plc1000 Sge-plc50
Sge-plc1000 Sge-plc50 circutor |
|
| References |
| |
| Metrics |
cvssV4_0
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: INCIBE
Published:
Updated: 2025-12-02T14:37:50.963Z
Reserved: 2025-10-15T12:06:11.744Z
Link: CVE-2025-11782
Updated: 2025-12-02T14:37:47.027Z
Status : Analyzed
Published: 2025-12-02T13:15:49.420
Modified: 2025-12-03T19:11:40.530
Link: CVE-2025-11782
No data.