Search Results (109 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-1772 1 Hitachienergy 1 Rtu500 Firmware 2026-02-25 N/A
RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges.
CVE-2026-1773 1 Hitachienergy 1 Rtu500 Firmware 2026-02-25 N/A
IEC 60870-5-104: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation.
CVE-2026-2459 1 Hitachienergy 1 Relion Reb500 2026-02-25 N/A
A vulnerability exists in REB500 for an authenticated user with Installer role to access and alter the contents of directories that the role is not authorized to do so.
CVE-2026-2460 1 Hitachienergy 1 Relion Reb500 2026-02-25 N/A
A vulnerability exists in REB500 for an authenticated user with low-level privileges to access and alter the content of directories by using the DAC protocol that the user is not authorized to do so.
CVE-2025-39205 1 Hitachienergy 1 Microscada X Sys600 2026-01-30 6.5 Medium
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.
CVE-2025-7740 1 Hitachienergy 1 Supros 2026-01-29 N/A
Default credentials vulnerability exists in SuprOS product. If exploited, this could allow an authenticated local attacker to use an admin account created during product deployment.
CVE-2025-39201 1 Hitachienergy 1 Microscada X Sys600 2026-01-26 6.1 Medium
A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.
CVE-2025-39202 1 Hitachienergy 1 Microscada X Sys600 2026-01-26 7.3 High
A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.
CVE-2025-39203 1 Hitachienergy 1 Microscada X Sys600 2026-01-26 6.5 Medium
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop.
CVE-2025-39204 1 Hitachienergy 1 Microscada X Sys600 2026-01-26 6.5 Medium
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user.
CVE-2024-41153 2 Hitachi Energy, Hitachienergy 7 Tro600, Tro610, Tro610 Firmware and 4 more 2025-11-04 7.2 High
Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the web UI can execute commands on the device with root privileges, far more extensive than what the write privilege intends.
CVE-2025-1036 1 Hitachienergy 1 Tropos 2025-10-30 N/A
Command injection vulnerability exists in the “Logging” page of the web-based configuration utility. An authenticated user with low privileged network access for the configuration utility can execute arbitrary commands on the underlying OS to obtain root SSH access to the TropOS 4th Gen device.
CVE-2025-1037 1 Hitachienergy 1 Tropos 2025-10-30 N/A
By making minor configuration changes to the TropOS 4th Gen device, an authenticated user with the ability to run user level shell commands can enable access via secure shell (SSH) to an unrestricted root shell. This is possible through abuse of a particular set of scripts and executables that allow for certain commands to be run as root from an unprivileged context.
CVE-2025-1038 1 Hitachienergy 1 Tropos 2025-10-30 N/A
The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device.
CVE-2025-10217 1 Hitachienergy 1 Asset Suite 2025-10-28 N/A
A vulnerability exists in Asset Suite for an authenticated user to manipulate the content of performance related log data or to inject crafted data in logfile for potentially carrying out further malicious attacks. Performance logging is typically enabled for troubleshooting purposes while resolving application performance related issues.
CVE-2024-2097 1 Hitachienergy 1 Modular Advanced Control For Hvdc 2025-10-21 7 High
An authenticated malicious client can send a special LINQ query to execute arbitrary code remotely (RCE) on the SCM server from List control, and execute the arbitrary code on the same system where SCMArchivedEventViewerTool is installed in the case of SCM Tools.
CVE-2024-4872 1 Hitachienergy 3 Microscada Pro Sys600, Microscada Sys600, Microscada X Sys600 2025-08-27 8.8 High
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential.
CVE-2024-3980 1 Hitachienergy 3 Microscada Pro Sys600, Microscada Sys600, Microscada X Sys600 2025-08-27 8.8 High
The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application.
CVE-2022-2513 1 Hitachienergy 6 650connectivitypackage, 670connectivitypackage, Gms600connectivitypackage and 3 more 2025-08-27 7.1 High
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs.
CVE-2022-3388 1 Hitachienergy 2 Microscada Pro Sys600, Microscada X Sys600 2025-07-23 8.8 High
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. An authenticated user can launch an administrator level remote code execution irrespective of the authenticated user's role.