| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability was found in FreeFloat FTP Server 1.0 and classified as critical. This issue affects some unknown processing of the component RECV Command Handler. The manipulation leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. |
| Improper Use of Validation Framework vulnerability in Tridium Niagara Framework on Windows, Linux, QNX, Tridium Niagara Enterprise Security on Windows, Linux, QNX allows Input Data Manipulation. This issue affects Niagara Framework: before 4.14.2, before 4.15.1, before 4.10.11; Niagara Enterprise Security: before 4.14.2, before 4.15.1, before 4.10.11. Tridium recommends upgrading to Niagara Framework and Enterprise Security versions 4.14.2u2, 4.15.u1, or 4.10u.11. |
| Improper Output Neutralization for Logs vulnerability in Tridium Niagara Framework on Windows, Linux, QNX, Tridium Niagara Enterprise Security on Windows, Linux, QNX allows Input Data Manipulation. This issue affects Niagara Framework: before 4.14.2, before 4.15.1, before 4.10.11; Niagara Enterprise Security: before 4.14.2, before 4.15.1, before 4.10.11. Tridium recommends upgrading to Niagara Framework and Enterprise Security versions 4.14.2u2, 4.15.u1, or 4.10u.11. |
| The Priva TopControl Suite contains predictable credentials for the SSH service, based on the Serial number. Which makes it possible for an attacker to calculate the login credentials for the Priva TopControll suite. |
| In Tenda RX3 V1.0br_V16.03.13.11 in the GetParentControlInfo function of the web url /goform/GetParentControlInfo, the manipulation of the parameter mac leads to stack overflow. |
| There is a stack overflow vulnerability in Tenda RX3 V1.0br_V16.03.13.11 In the fromSetWifiGusetBasic function of the web url /goform/ WifiGuestSet, the manipulation of the parameter shareSpeed leads to stack overflow. |
| TOTOLINK AC1200 Wireless Dual Band Gigabit Router firmware A3100R V4.1.2cu.5247_B20211129, in the cgi function `setNoticeCfg` of the file `/lib/cste_modules/system.so`, the length of the user input string `NoticeUrl` is not checked. This can lead to a buffer overflow, allowing attackers to construct malicious HTTP or MQTT requests to cause a denial-of-service attack. |
| Ashlar-Vellum Cobalt CO File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Ashlar-Vellum Cobalt. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the parsing of CO files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.
. Was ZDI-CAN-17865. |
| DI-8100 v16.07.26A1 is vulnerable to Buffer Overflow In the ip_position_asp function via the ip parameter. |
| Linksys WRT54G v4.21.5 has a stack overflow vulnerability in get_merge_mac function. |
| Weak Authentication vulnerability in Drupal Two-factor Authentication (TFA) allows Authentication Abuse.This issue affects Two-factor Authentication (TFA): from 0.0.0 before 1.5.0. |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions). Affected devices do not properly handle multiple incoming Profinet packets received in rapid succession.
An unauthenticated remote attacker can exploit this flaw by sending multiple packets in a very short time frame, which leads to a crash of the dcpd process. |
| Valid Host header field can cause Apache Traffic Server to crash on some platforms.
This issue affects Apache Traffic Server: from 9.2.0 through 9.2.5.
Users are recommended to upgrade to version 9.2.6, which fixes the issue, or 10.0.2, which does not have the issue. |
| A integer overflow or wraparound in Fortinet FortiOS versions 7.2.0 through 7.2.7, versions 7.0.0 through 7.0.14 may allow a remote unauthenticated attacker to crash the csfd daemon via a specially crafted request. |
| A buffer over-read in Fortinet FortiOS versions 7.4.0 through 7.4.3, versions 7.2.0 through 7.2.7, and versions 7.0.0 through 7.0.14 may allow a remote unauthenticated attacker to crash the FGFM daemon via a specially crafted request, under rare conditions that are outside of the attacker's control. |
| Memory corruption in WLAN due to buffer copy without checking size of input while parsing keys in Snapdragon Connectivity, Snapdragon Mobile |
| Insufficient Granularity of Access Control vulnerability in Drupal Email Contact allows Forceful Browsing.This issue affects Email Contact: from 0.0.0 before 2.0.4. |
| Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* |
| Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* |
| Denial of service due to improper handling of malformed input. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 40077. |