| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767 |
| A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276 |
| A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet |
| A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet |
| A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module. |
| Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded. |
| Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured. |
| A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report. |
| A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge of javascript code when crafted malicious parameters are submitted to the charging station web server. |
| Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP. |
| Cscape (All versions prior to 9.90 SP4) lacks proper validation of user-supplied data when parsing project files. This could lead to memory corruption. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| A privilege escalation vulnerability impacting the Google Exposure Notification Verification Server (versions prior to 0.23.1), allows an attacker who (1) has UserWrite permissions and (2) is using a carefully crafted request or malicious proxy, to create another user with higher privileges than their own. This occurs due to insufficient checks on the allowed set of permissions. The new user creation event would be captured in the Event Log. |
| Information leakage vulnerability in NetIQ Access Manager prior to 5.0.1 and 4.5.4 |
| A potential vulnerability has been identified for OpenText Operations Bridge Reporter. The vulnerability could be exploited to inject malicious SQL queries. An attack requires to be an authenticated administrator of OBR with network access to the OBR web application. |
| There is an Input verification vulnerability in Huawei Smartphone.Successful exploitation of this vulnerability may affect service availability. |
| A component of the HarmonyOS has a Improper Input Validation vulnerability. Local attackers may exploit this vulnerability to read at any address. |
| A component of the HarmonyOS has a Improper Input Validation vulnerability. Local attackers may exploit this vulnerability to cause out-of-bounds write. |
| A component of the HarmonyOS has a Improper Input Validation vulnerability. Local attackers may exploit this vulnerability to read at any address. |
| There is an Input Verification Vulnerability in Huawei Smartphone.Successful exploitation of this vulnerability may cause the system to reset. |
| There is an Input Verification Vulnerability in Huawei Smartphone.Successful exploitation of this vulnerability may cause code injection. |