Search Results (19966 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-22824 1 Schneider-electric 1 Interactive Graphical Scada System Data Collector 2024-11-21 7.5 High
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
CVE-2021-22809 1 Schneider-electric 1 Guicon 2024-11-21 5.5 Medium
A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
CVE-2021-22802 1 Schneider-electric 1 Interactive Graphical Scada System Data Collector 2024-11-21 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CVE-2021-22790 1 Schneider-electric 49 Modicon M340 Bmxp341000, Modicon M340 Bmxp342010, Modicon M340 Bmxp342020 and 46 more 2024-11-21 6.5 Medium
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).
CVE-2021-22771 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2024-11-21 7.3 High
A CWE-1236: Improper Neutralization of Formula Elements in a CSV File vulnerability exists in Easergy T300 with firmware V2.7.1 and older that would allow arbitrary command execution.
CVE-2021-22757 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22756 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22753 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is being parsed by IGSS Definition.
CVE-2021-22673 1 Ti 7 Cc3100 Software Development Kit, Cc3200 Software Development Kit, Simplelink Cc13x0 Software Development Kit and 4 more 2024-11-21 8.0 High
The affected product is vulnerable to stack-based buffer overflow while processing over-the-air firmware updates from the CDN server, which may allow an attacker to remotely execute code on the SimpleLink Wi-Fi (MSP432E4 SDK: v4.20.00.12 and prior, CC32XX SDK v4.30.00.06 and prior, CC13X0 SDK versions prior to v4.10.03, CC13X2 and CC26XX SDK versions prior to v4.40.00, CC3200 SDK v1.5.0 and prior, CC3100 SDK v1.3.0 and prior).
CVE-2021-22668 1 Deltaww 1 Cncsoft Screeneditor 2024-11-21 9.8 Critical
Delta Industrial Automation CNCSoft ScreenEditor Versions 1.01.28 (with ScreenEditor Version 1.01.2) and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.
CVE-2021-22666 1 Fatek 1 Fvdesigner 2024-11-21 7.8 High
Fatek FvDesigner Version 1.5.76 and prior is vulnerable to a stack-based buffer overflow while project files are being processed, allowing an attacker to craft a special project file that may permit arbitrary code execution.
CVE-2021-22663 2 Hornerautomation, Siemens 2 Cscape, Cscape 2024-11-21 7.8 High
Cscape (All versions prior to 9.90 SP3.5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2021-22660 1 Criticalmanufacturing 1 Cncsoft-b 2024-11-21 7.8 High
CNCSoft-B Versions 1.0.0.3 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
CVE-2021-22659 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 Firmware 2024-11-21 8.6 High
Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a denial-of-service condition. The FAULT LED will flash RED and communications may be lost. Recovery from denial-of-service condition requires the fault to be cleared by the user.
CVE-2021-22655 1 Fujielectric 2 V-server, V-simulator 2024-11-21 7.8 High
Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
CVE-2021-22643 2 Luxion, Siemens 8 Keyshot, Keyshot Network Rendering, Keyshot Viewer and 5 more 2024-11-21 7.8 High
Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.
CVE-2021-22641 1 Fujielectric 2 V-server, V-simulator 2024-11-21 7.8 High
A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
CVE-2021-22638 1 Fatek 1 Fvdesigner 2024-11-21 7.8 High
Fatek FvDesigner Version 1.5.76 and prior is vulnerable to an out-of-bounds read while processing project files, allowing an attacker to craft a special project file that may permit arbitrary code execution.
CVE-2021-22637 1 Fujielectric 2 V-server, V-simulator 2024-11-21 7.8 High
Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).
CVE-2021-22564 1 Libjxl Project 1 Libjxl 2024-11-21 4.5 Medium
For certain valid JPEG XL images with a size slightly larger than an integer number of groups (256x256 pixels) when processing the groups out of order the decoder can perform an out of bounds copy of image pixels from an image buffer in the heap to another. This copy can occur when processing the right or bottom edges of the image, but only when groups are processed in certain order. Groups can be processed out of order in multi-threaded decoding environments with heavy thread load but also with images that contain the groups in an arbitrary order in the file. It is recommended to upgrade past 0.6.0 or patch with https://github.com/libjxl/libjxl/pull/775