| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Adobe InDesign versions 17.2.1 (and earlier) and 16.4.1 (and earlier) are affected by an out-of-bounds write vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file. |
| libImaging/TgaRleDecode.c in Pillow 9.1.0 has a heap buffer overflow in the processing of invalid TGA image files. |
| Out-of-bounds write vulnerability exists in the simulator module contained in the graphic editor 'V-SFT' versions prior to v6.1.6.0, which may allow an attacker to obtain information and/or execute arbitrary code by having a user to open a specially crafted image file. |
| There is an invalid memory access in the TextLine class in TextOutputDev.cc in Xpdf 4.0.4 because the text extractor mishandles characters at large y coordinates. It can be triggered by (for example) sending a crafted pdf file to the pdftotext binary, which allows a remote attacker to cause a Denial of Service (Segmentation fault) or possibly have unspecified other impact. |
| If Apache HTTP Server 2.4.53 is configured to do transformations with mod_sed in contexts where the input to mod_sed may be very large, mod_sed may make excessively large memory allocations and trigger an abort. |
| The LAN-side Web-Configuration Interface has Stack-based Buffer Overflow vulnerability in the D-Link Wi-Fi router firmware DIR-890L DIR890LA1_FW107b09.bin and previous versions. The function created at 0x17958 of /htdocs/cgibin will call sprintf without checking the length of strings in parameters given by HTTP header and can be controlled by users easily. The attackers can exploit the vulnerability to carry out arbitrary code by means of sending a specially constructed payload to port 49152. |
| Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request. |
| Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request. |
| Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/WifiExtraSet request. |
| Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request. |
| Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set |
| Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat |
| Tenda Technology Co.,Ltd HG6 3.3.0-210926 was discovered to contain a command injection vulnerability via the pingAddr and traceAddr parameters. This vulnerability is exploited via a crafted POST request. |
| An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. An OS injection vulnerability exists within the web interface, allowing an attacker with valid credentials to execute arbitrary shell commands. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-on" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| A stack-based buffer overflow vulnerability [CWE-121] in the CA sign functionality of FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 and below may allow an authenticated attacker to achieve arbitrary code execution via specifically crafted password. |
| An improper neutralization of special elements used in an os command ('OS Command Injection') [CWE-78] in FortiWeb 7.0.0 through 7.0.1, 6.3.0 through 6.3.19, 6.4 all versions may allow an authenticated attacker to execute arbitrary shell code as `root` user via crafted HTTP requests. |