Search Results (171 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-4088 1 Mitsubishielectric 1 Gx Works3 2024-11-21 9.3 Critical
Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder.
CVE-2023-0525 1 Mitsubishielectric 14 Gs21, Gs21 Firmware, Gs25 and 11 more 2024-11-21 7.5 High
Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled.
CVE-2022-40267 1 Mitsubishielectric 106 Fx5s-30mr\/es, Fx5s-30mr\/es Firmware, Fx5s-30mt\/es and 103 more 2024-11-21 5.9 Medium
Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-xMy/z (x=24,40,60, y=T,R, z=ES,ESS) versions 1.042 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-xMy/ES-A (x=24,40,60, y=T,R) versions 1.043 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-xMy/z (x=30,40,60,80, y=T,R, z=ES,ESS) versions 1.003 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU versions 33 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU versions 66 and prior allows a remote unauthenticated attacker to access the Web server function by guessing the random numbers used for authentication from several used random numbers.
CVE-2022-25162 2 Mitsubhishielectric, Mitsubishielectric 194 Melsec Iq-fx5u-32mr\/ds, Melsec Iq-fx5u-32mr\/ds Firmware, Melsec Iq-fx5u-32mr\/dss and 191 more 2024-11-21 5.3 Medium
Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/z(x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later and versions prior to 1.270, Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/z(x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179**** and prior and versions prior to 1.073, MELSEC iQ-F series FX5UC-xMy/z(x=32,64,96, y=T,R, z=D,DSS) with serial number 17X**** or later and versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-xMy/z(x=32,64,96, y=T,R, z=D,DSS) with serial number 179**** and prior and versions prior to 1.073, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MT/DS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MT/DSS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MR/DS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UJ-xMy/z(x=24,40,60, y=T,R, z=ES,ESS) versions prior to 1.030, Mitsubishi Electric MELSEC iQ-F series FX5UJ-xMy/ES-A(x=24,40,60, y=T,R) versions prior to 1.031 and Mitsubishi Electric MELSEC iQ-F series FX5S-xMy/z(x=30,40,60,80, y=T,R, z=ES,ESS) version 1.000 allows a remote unauthenticated attacker to cause a temporary DoS condition for the product's communication by sending specially crafted packets.
CVE-2022-25161 2 Mitsubhishielectric, Mitsubishielectric 194 Melsec Iq-fx5u-32mr\/ds, Melsec Iq-fx5u-32mr\/ds Firmware, Melsec Iq-fx5u-32mr\/dss and 191 more 2024-11-21 8.6 High
Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/z(x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later and versions prior to 1.270, Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/z(x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179**** and prior and versions prior to 1.073, MELSEC iQ-F series FX5UC-xMy/z(x=32,64,96, y=T,R, z=D,DSS) with serial number 17X**** or later and versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-xMy/z(x=32,64,96, y=T,R, z=D,DSS) with serial number 179**** and prior and versions prior to 1.073, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MT/DS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MT/DSS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UC-32MR/DS-TS versions prior to 1.270, Mitsubishi Electric MELSEC iQ-F series FX5UJ-xMy/z(x=24,40,60, y=T,R, z=ES,ESS) versions prior to 1.030, Mitsubishi Electric MELSEC iQ-F series FX5UJ-xMy/ES-A(x=24,40,60, y=T,R) versions prior to 1.031 and Mitsubishi Electric MELSEC iQ-F series FX5S-xMy/z(x=30,40,60,80, y=T,R, z=ES,ESS) version 1.000 allows a remote unauthenticated attacker to cause a DoS condition for the product's program execution or communication by sending specially crafted packets. System reset of the product is required for recovery.
CVE-2022-25160 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-11-21 5.9 Medium
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to disclose a file in a legitimate user's product by using previously eavesdropped cleartext information and to counterfeit a legitimate user’s system.
CVE-2022-25159 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-11-21 8.1 High
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to login to the product by replay attack.
CVE-2022-25158 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-11-21 9.1 Critical
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GF11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GP21(S)-SX all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote attacker to disclose or tamper with a file in which password hash is saved in cleartext.
CVE-2022-25157 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-11-21 9.1 Critical
Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GF11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GP21(S)-SX all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to disclose or tamper with the information in the product by using an eavesdropped password hash.
CVE-2022-25156 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-11-21 8.1 High
Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by using a password reversed from a previously eavesdropped password hash.
CVE-2022-25155 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2024-11-21 8.1 High
Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GN11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GN11-EIP all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by replaying an eavesdropped password hash.
CVE-2022-24946 1 Mitsubishielectric 64 L02cpu, L02cpu-p, L02cpu-p Firmware and 61 more 2024-11-21 7.5 High
Improper Resource Locking vulnerability in Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V firmware versions "16" and prior, Mitsubishi Electric MELSEC-Q Series Q03UDECPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/10/13/20/26/50/100UDEHCPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/13/26UDPVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q12DCCPU-V all versions, Mitsubishi Electric MELSEC-Q Series Q24DHCCPU-V(G) all versions, Mitsubishi Electric MELSEC-Q Series Q24/26DHCCPU-LS all versions, Mitsubishi Electric MELSEC-L series L02/06/26CPU(-P) the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-L series L26CPU-(P)BT the first 5 digits of serial number "24051" and prior and Mitsubishi Electric MELIPC Series MI5122-VW firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial of service (DoS) condition in Ethernet communications by sending specially crafted packets. A system reset of the products is required for recovery.
CVE-2022-23129 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2024-11-21 5.5 Medium
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.
CVE-2022-23128 2 Iconics, Mitsubishielectric 5 Analytix, Genesis64, Hyper Historian and 2 more 2024-11-21 9.8 Critical
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.
CVE-2022-23127 2 Iconics, Mitsubishielectric 2 Mobilehmi, Mc Works64 2024-11-21 6.1 Medium
Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL.
CVE-2021-27041 3 Autodesk, Iconics, Mitsubishielectric 13 Advance Steel, Autocad, Autocad Architecture and 10 more 2024-11-21 7.8 High
A maliciously crafted DWG file can be used to write beyond the allocated buffer while parsing DWG files. This vulnerability can be exploited to execute arbitrary code
CVE-2021-27040 3 Autodesk, Iconics, Mitsubishielectric 13 Advance Steel, Autocad, Autocad Architecture and 10 more 2024-11-21 3.3 Low
A maliciously crafted DWG file can be forced to read beyond allocated boundaries when parsing the DWG file. This vulnerability can be exploited to execute arbitrary code.
CVE-2021-20613 1 Mitsubishielectric 6 Fx3u-enet, Fx3u-enet-l, Fx3u-enet-l Firmware and 3 more 2024-11-21 7.5 High
Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.
CVE-2021-20612 1 Mitsubishielectric 6 Fx3u-enet, Fx3u-enet-l, Fx3u-enet-l Firmware and 3 more 2024-11-21 7.5 High
Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.
CVE-2021-20608 1 Mitsubishielectric 1 Gx Works2 2024-11-21 7.5 High
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file.