| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The VAPIX API port.cgi did not have sufficient input validation, which may result in process crashes and impact usability. This vulnerability can only be exploited after authenticating with a viewer- operator- or administrator-privileged service account. |
| Improper access control in the fTPM driver in the trusted OS could allow a privileged attacker to corrupt system memory, potentially leading to loss of integrity, confidentiality, or availability. |
| The Net::IPAddress::Util module before 5.000 for Perl does not properly consider extraneous zero characters in an IP address string, which (in some situations) allows attackers to bypass access control that is based on IP addresses. |
|
A vulnerability was reported
in a system recovery bootloader that was part of the Lenovo preloaded Windows 7 and 8 operating systems from 2012 to 2014
that could allow a privileged attacker with local access to modify the boot manager and escalate privileges.
|
| The Secure Flag passed to Versal™ Adaptive SoC’s Trusted Firmware for Cortex®-A processors (TF-A) for Arm’s Power State Coordination Interface (PSCI) commands were incorrectly set to secure instead of using the processor’s actual security state. This would allow the PSCI requests to appear they were from processors in the secure state instead of the non-secure state. |
| Westermo WeOS 5 through 5.23.0 allows a reboot via a malformed ESP packet. |
| Improper input validation in AMD Power Management Firmware (PMFW) could allow a privileged attacker from Guest VM to send arbitrary input data potentially causing a GPU Reset condition. |
| Net::CIDR::Set versions 0.10 through 0.13 for Perl does not properly handle leading zero characters in IP CIDR address strings, which could allow attackers to bypass access control that is based on IP addresses.
Leading zeros are used to indicate octal numbers, which can confuse users who are intentionally using octal notation, as well as users who believe they are using decimal notation.
Net::CIDR::Set used code from Net::CIDR::Lite, which had a similar vulnerability CVE-2021-47154. |
| Improper input validation in the GPU driver could allow an attacker to exploit a heap overflow potentially resulting in arbitrary code execution. |
| A vulnerability has been found in ywxbear PHP-Bookstore-Website-Example and PHP Basic BookStore Website up to 0e0b9f542f7a2d90a8d7f8c83caca69294e234e4. This issue affects some unknown processing of the file /index.php of the component Quantity Handler. Such manipulation leads to improper validation of specified quantity in input. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases. |
| The SAP Approuter Node.js package version v16.7.1 and before is vulnerable to Authentication bypass. When trading an authorization code an attacker can steal the session of the victim by injecting malicious payload causing High impact on confidentiality and integrity of the application |
| A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0) (All versions < V4.7). Affected devices do not process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |
| Sandboxie 5.49.7 contains a denial of service vulnerability that allows attackers to crash the application by overflowing the container folder input field. Attackers can paste a large buffer of repeated characters into the Sandbox container folder setting to trigger an application crash. |
| A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IY8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. |
| An unauthenticated attacker who can connect to the Web Services feature (HTTP TCP port 80) can issue a WS-Scan SOAP request containing an unexpected JobToken value which will crash the target device. The device will reboot, after which the attacker can reissue the command to repeatedly crash the device. |
| Improper Validation of Specified Quantity in Input vulnerability in Tips and Tricks HQ WP Express Checkout (Accept PayPal Payments) allows Manipulating Hidden Fields.This issue affects WP Express Checkout (Accept PayPal Payments): from n/a through 2.3.7. |
| A key used in logging.json does not follow the least privilege principle by default and is exposed to local users in the Rapid7 Platform. This allows an attacker with local access to a machine with the logging.json file to use that key to authenticate to the platform with high privileges. This was fixed in the Rapid7 platform starting 3 April 2024 via the introduction of a restricted role and the removal of automatic API key generation on installation of an agent. |
| An unauthenticated attacker who can connect to TCP port 9100 can issue a Printer Job Language (PJL) command that will crash the target device. The device will reboot, after which the attacker can reissue the command to repeatedly crash the device. A malformed PJL variable FORMLINES is set to a non number value causing the target to crash. |
| The security state of the calling processor into Trusted Firmware (TF-A) is not used and could potentially allow non-secure processors access to secure memories, access to crypto operations, and the ability to turn on and off subsystems within the SOC. |
| An unauthenticated remote attacker can send a specially crafted Modbus read command to the device which leads to a denial of service. |