| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
|
SonicOS post-authentication stack-based buffer overflow vulnerability in the getBookmarkList.json URL endpoint leads to a firewall crash.
|
| A memory corruption vulnerability in ArubaOS-Switch could lead to unauthenticated remote code execution by receiving specially crafted packets. Successful exploitation of this vulnerability results in the ability to execute arbitrary code as a privileged user on the underlying operating system. |
|
ASUS RT-AC86U Traffic Analyzer - Apps analysis function has insufficient filtering of special character. A remote attacker with regular user privilege can exploit this vulnerability to perform command injection attack to execute arbitrary commands, disrupt system or terminate services.
|
|
ASUS RT-AC86U Traffic Analyzer - Statistic function has insufficient filtering of special character. A remote attacker with regular user privilege can exploit this vulnerability to perform command injection attack to execute arbitrary commands, disrupt system or terminate services.
|
| Archer C5 firmware all versions and Archer C7 firmware versions prior to 'Archer C7(JP)_V2_230602' allow a network-adjacent authenticated attacker to execute arbitrary OS commands. Note that Archer C5 is no longer supported, therefore the update for this product is not provided. |
| OS command injection vulnerability in FURUNO SYSTEMS wireless LAN access point devices allows an authenticated user to execute an arbitrary OS command that is not intended to be executed from the web interface by sending a specially crafted request. Affected products and versions are as follows: ACERA 1320 firmware ver.01.26 and earlier, ACERA 1310 firmware ver.01.26 and earlier, ACERA 1210 firmware ver.02.36 and earlier, ACERA 1150i firmware ver.01.35 and earlier, ACERA 1150w firmware ver.01.35 and earlier, ACERA 1110 firmware ver.01.76 and earlier, ACERA 1020 firmware ver.01.86 and earlier, ACERA 1010 firmware ver.01.86 and earlier, ACERA 950 firmware ver.01.60 and earlier, ACERA 850F firmware ver.01.60 and earlier, ACERA 900 firmware ver.02.54 and earlier, ACERA 850M firmware ver.02.06 and earlier, ACERA 810 firmware ver.03.74 and earlier, and ACERA 800ST firmware ver.07.35 and earlier. They are affected when running in ST(Standalone) mode. |
| Uncontrolled resource consumption in Zoom Team Chat for Zoom Desktop Client for Windows and Zoom VDI Client may allow an unauthenticated user to conduct a disclosure of information via network access. |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. |
| GNU gdb (GDB) 13.0.50.20220805-git was discovered to contain a heap buffer overflow via the function pe_as16() at /gdb/coff-pe-read.c. |
| GNU gdb (GDB) 13.0.50.20220805-git was discovered to contain a stack overflow via the function ada_decode at /gdb/ada-lang.c. |
| NTSC-CRT 2.2.1 has an integer overflow and out-of-bounds write in loadBMP in bmp_rw.c because a file's width, height, and BPP are not validated. NOTE: the vendor's perspective is "this main application was not intended to be a well tested program, it's just something to demonstrate it works and for the user to see how to integrate it into their own programs." |
| Buffer Overflwo vulnerability in JerryScript Project jerryscript v.3.0.0 allows a remote attacker to execute arbitrary code via the scanner_is_context_needed component in js-scanner-until.c. |
| Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. |
| Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function. |
| Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im. |
| Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. |
| Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. |
| Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. |
| Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function. |
| Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. |