| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to obtain sensitive server and statistics information via unspecified vectors. |
| Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection. |
| Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship. |
| The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. |
| The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. |
| SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. |
| Unspecified vulnerability in the client library in Siemens COMOS 9.2 before 9.2.0.6.10 and 10.0 before 10.0.3.0.4 allows local users to obtain unintended write access to the database by leveraging read access. |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials. |
| A vulnerability has been identified in Unicam FX (All versions). The windows installer agent used in affected product contains incorrect use of privileged APIs that trigger the Windows Console Host (conhost.exe) as a child process with SYSTEM privileges. This could be exploited by an attacker to perform a local privilege escalation attack. |
| A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected component does not correctly validate the root path on folder related operations, allowing to modify files and folders outside the intended root directory.
This could allow an unauthenticated remote attacker to execute file operations of files outside of the specified root folder. Chained with CVE-2022-43513 this could allow Remote Code Execution. |
| A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected components allow to rename license files with user chosen input without authentication.
This could allow an unauthenticated remote attacker to rename and move files as SYSTEM user. |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component. |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component. |
| Buffer overflow in the SYSTEM_CREATE_INSTANCE function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. |
| Buffer overflow in the RFC_START_GUI function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. |
| Buffer overflow in the RFC_START_PROGRAM function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. |
| The TRUSTED_SYSTEM_SECURITY function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to verify the existence of users and groups on systems and domains via unspecified vectors, a different vulnerability than CVE-2006-6010. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. |
| Multiple cross-site scripting (XSS) vulnerabilities in the Siemens Gigaset SE361 WLAN router with firmware 1.00.0 allow remote attackers to inject arbitrary web script or HTML via the portion of the URI immediately following the filename for (1) a GIF filename, which triggers display of the GIF file in text format and an unspecified denial of service (crash); or (2) the login.tri filename, which triggers a continuous loop of the browser attempting to visit the login page. |
| OpenSC before 0.11.5 uses weak permissions (ADMIN file control information of 00) for the 5015 directory on smart cards and USB crypto tokens running Siemens CardOS M4, which allows physically proximate attackers to change the PIN. |
| The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723. |