| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability located in the deviceName parameter of the formSetDeviceName function. |
| Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function. |
| Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function. |
| A vulnerability has been found in Tenda AC15 15.03.05.19 in the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src leads to stack-based buffer overflow. |
| Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the SYSPS parameter at /goform/SysToolChangePwd. |
| There is an unauthorized buffer overflow vulnerability in Tenda AX12 v22.03.01.21 _ cn. This vulnerability can cause the web service not to restart or even execute arbitrary code. It is a different vulnerability from CVE-2022-2414. |
| A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution. |
| Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function. |
| Tenda i12 V1.0.0.10(3805) was discovered to contain a buffer overflow via the list parameter in the formwrlSSIDset function. |
| Tenda i12 V1.0.0.10(3805) was discovered to contain a buffer overflow via the funcpara1 parameter in the formSetCfm function. |
| Tenda i12 V1.0.0.10(3805) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterSet function. |
| Tenda AC6 15.03.05.16_multi is vulnerable to Buffer Overflow in the sub_452A4 function. |
| There is a RCE vulnerability in Tenda AC6 15.03.05.16_multi. In the formexeCommand function, the parameter cmdinput will cause remote command execution. |
| Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function. |
| A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
| Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. |
| Tenda AC6 v2.0 V15.03.06.50 was discovered to contain a buffer overflow in the function 'formSetPPTPServer'. |
| Tenda FH1201 v1.2.0.14 has a stack buffer overflow vulnerability in `formWrlExtraGet`. |