Search Results (72558 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2019-10978 1 Redlion 1 Crimson 2024-11-21 7.8 High
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that operates outside of the designated memory area.
CVE-2019-10977 1 Mitsubishielectric 2 Qj71e71-100, Qj71e71-100 Firmware 2024-11-21 7.5 High
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.
CVE-2019-10969 1 Moxa 2 Edr-810, Edr-810 Firmware 2024-11-21 7.2 High
Moxa EDR 810, all versions 5.1 and prior, allows an authenticated attacker to abuse the ping feature to execute unauthorized commands on the router, which may allow an attacker to perform remote code execution.
CVE-2019-10967 1 Emerson 2 Ovation Ocr400, Ovation Ocr400 Firmware 2024-11-21 8.8 High
In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a stack-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long file name from the LIST command to the FTP service, which may cause the service to overwrite buffers, leading to remote code execution and escalation of privileges.
CVE-2019-10965 1 Emerson 2 Ovation Ocr400, Ovation Ocr400 Firmware 2024-11-21 8.8 High
In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a heap-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long command to the FTP service, which may cause memory corruption that halts the controller or leads to remote code execution and escalation of privileges.
CVE-2019-10961 1 Advantech 1 Webaccess Hmi Designer 2024-11-21 8.8 High
In Advantech WebAccess HMI Designer Version 2.1.9.23 and prior, processing specially crafted MCR files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, allowing remote code execution.
CVE-2019-10960 1 Zebra 16 220xi4, 220xi4 Firmware, Zt220 and 13 more 2024-11-21 7.5 High
Zebra Industrial Printers All Versions, Zebra printers are shipped with unrestricted end-user access to front panel options. If the option to use a passcode to limit the functionality of the front panel is applied, specially crafted packets could be sent over the same network to a port on the printer and the printer will respond with an array of information that includes the front panel passcode for the printer. Once the passcode is retrieved, an attacker must have physical access to the front panel of the printer to enter the passcode to access the full functionality of the front panel.
CVE-2019-10958 1 Geutebrueck 22 G-cam Ebc-2110, G-cam Ebc-2110 Firmware, G-cam Ebc-2111 and 19 more 2024-11-21 7.2 High
Geutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated attacker with access to network configuration to supply system commands to the server, leading to remote code execution as root.
CVE-2019-10956 1 Geutebrueck 22 G-cam Ebc-2110, G-cam Ebc-2110 Firmware, G-cam Ebc-2111 and 19 more 2024-11-21 7.2 High
Geutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated user, using a specially crafted URL command, to execute commands as root.
CVE-2019-10954 1 Rockwellautomation 10 Armor Compact Guardlogix 5370, Armor Compact Guardlogix 5370 Firmware, Compact Guardlogix 5370 and 7 more 2024-11-21 7.5 High
An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.
CVE-2019-10953 5 Abb, Phoenixcontact, Schneider-electric and 2 more 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more 2024-11-21 7.5 High
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
CVE-2019-10951 1 Deltaww 1 Cncsoft Screeneditor 2024-11-21 7.8 High
Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap.
CVE-2019-10947 1 Deltaww 1 Cncsoft Screeneditor 2024-11-21 7.8 High
Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. This may occur because CNCSoft lacks user input validation before copying data from project files onto the stack.
CVE-2019-10943 1 Siemens 22 Simatic Et 200sp Open Controller Cpu 1515sp Pc, Simatic Et 200sp Open Controller Cpu 1515sp Pc2, Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware and 19 more 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
CVE-2019-10942 1 Siemens 6 Scalance X-200, Scalance X-200 Firmware, Scalance X-200irt and 3 more 2024-11-21 8.6 High
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
CVE-2019-10937 1 Siemens 2 Simatic Tdc Cp51m1, Simatic Tdc Cp51m1 Firmware 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC TDC CP51M1 (All versions < V1.1.7). An attacker with network access to the device could cause a Denial-of-Service condition by sending a specially crafted UDP packet. The vulnerability affects the UDP communication of the device. The security vulnerability could be exploited without authentication. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-10936 1 Siemens 130 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200 and 127 more 2024-11-21 7.5 High
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
CVE-2019-10934 1 Siemens 1 Totally Integrated Automation Portal 2024-11-21 7.8 High
A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-10931 1 Siemens 28 6md85, 6md86, 6md89 and 25 more 2024-11-21 7.5 High
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
CVE-2019-10925 1 Siemens 4 Simatic Mv420, Simatic Mv420 Firmware, Simatic Mv440 and 1 more 2024-11-21 7.1 High
A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.