| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Missing authorization vulnerability in the system components. Successful exploitation of this vulnerability will affect confidentiality. |
| Within SAP S/4HANA - versions S4CORE 101, 102, 103, 104, 105, 106, SAPSCORE 127, the application business partner extension for Spain/Slovakia does not perform necessary authorization checks for a low privileged authenticated user over the network, resulting in escalation of privileges leading to low impact on confidentiality and integrity of the data. |
| SAP Financial Consolidation - version 1010,�does not perform necessary authorization checks for an authenticated user, resulting in escalation of privileges.
|
| The application SAP Enterprise Extension Defense Forces & Public Security - versions 605, 606, 616,617,618, 802, 803, 804, 805, 806, does not perform necessary authorization checks for an authenticated user over the network, resulting in escalation of privileges leading to a limited impact on confidentiality. |
| Due to improper authorization check, business users who are using Israeli File from SHAAM program (/ATL/VQ23 transaction), are granted more than needed authorization to perform certain transaction, which may lead to users getting access to data that would otherwise be restricted. |
| A Incorrect Authorization vulnerability in chkstat of SUSE Linux Enterprise Server 12-SP5; openSUSE Leap 15.3, openSUSE Leap 15.4, openSUSE Leap Micro 5.2 did not consider group writable path components, allowing local attackers with access to a group what can write to a location included in the path to a privileged binary to influence path resolution. This issue affects: SUSE Linux Enterprise Server 12-SP5 permissions versions prior to 20170707. openSUSE Leap 15.3 permissions versions prior to 20200127. openSUSE Leap 15.4 permissions versions prior to 20201225. openSUSE Leap Micro 5.2 permissions versions prior to 20181225. |
| A missing permission check in Jenkins SSH Plugin 2.6.1 and earlier allows attackers with Overall/Read permission to connect to an attacker-specified SSH server using attacker-specified credentials IDs obtained through another method, capturing credentials stored in Jenkins. |
| A missing permission check in Jenkins SSH Plugin 2.6.1 and earlier allows attackers with Overall/Read permission to enumerate credentials IDs of credentials stored in Jenkins. |
| Jenkins GitLab Plugin 1.5.31 and earlier does not perform a permission check in an HTTP endpoint, allowing attackers with Overall/Read permission to enumerate credentials IDs of credentials stored in Jenkins. |
| Jenkins Blue Ocean Plugin 1.25.3 and earlier does not perform a permission check in several HTTP endpoints, allowing attackers with Overall/Read permission to connect to an attacker-specified HTTP server. |
| Jenkins WMI Windows Agents Plugin 1.8 and earlier includes the Windows Remote Command library does not implement access control, potentially allowing users to start processes even if they're not allowed to log in. |
| Missing caller check in Smart Things prior to version 1.7.85.12 allows attacker to access senstive information remotely using javascript interface API. |
| Improper access control vulnerability in My Files prior to version 13.1.00.193 allows attackers to access arbitrary private files in My Files application. |
| The Linux kernel before 5.17.2 mishandles seccomp permissions. The PTRACE_SEIZE code path allows attackers to bypass intended restrictions on setting the PT_SUSPEND_SECCOMP flag. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-on" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| Rescue Dispatch Management System 1.0 is vulnerable to Incorrect Access Control via http://localhost/rdms/admin/?page=system_info. |
| An incorrect handling of the supplementary groups in the Buildah container engine might lead to the sensitive information disclosure or possible data modification if an attacker has direct access to the affected container where supplementary groups are used to set access permissions and is able to execute a binary code in that container. |