| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. |
| Pharmacy Management System v1.0 was discovered to contain a remote code execution (RCE) vulnerability via the component /php_action/editProductImage.php. This vulnerability allows attackers to execute arbitrary code via a crafted image file. |
| FUDforum 3.1.2 is vulnerable to Remote Code Execution through Upload File feature of File Administration System in Admin Control Panel. |
| Webmin through 1.991, when the Authentic theme is used, allows remote code execution when a user has been manually created (i.e., not created in Virtualmin or Cloudmin). This occurs because settings-editor_write.cgi does not properly restrict the file parameter. |
| In Afian Filerun 20220202 Changing the "search_tika_path" variable to a custom (and previously uploaded) jar file results in remote code execution in the context of the webserver user. |
| A Remote Code Execution (RCE) vulnerability exists in waimairen 9.1 via wx.php |
| Proietti Tech srl Planet Time Enterprise 4.2.0.1,4.2.0.0,4.1.0.0,4.0.0.0,3.3.1.0,3.3.0.0 is vulnerable to Remote code execution via the Viewstate parameter. |
| Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service. |
| Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability. |
| Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position. |
| A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) |
| In TP-Link Router AX50 firmware 210730 and older, import of a malicious backup file via web interface can lead to remote code execution due to improper validation. |
| Prime95 30.7 build 9 suffers from a Buffer Overflow vulnerability that could lead to Remote Code Execution. |
| The ImageMagick Engine plugin for WordPress is vulnerable to remote code execution via the 'cli_path' parameter in versions up to, and including 1.7.5. This makes it possible for unauthenticated users to run arbitrary commands leading to remote command execution, granted they can trick a site administrator into performing an action such as clicking on a link. This makes it possible for an attacker to create and or modify files hosted on the server which can easily grant attackers backdoor access to the affected server. |
| Improper neutralization of special elements used in a user input allows an authenticated malicious user to perform remote code execution in the host system. This vulnerability impacts SonicWall Switch 1.1.1.0-2s and earlier versions |
| The OpenSSL 3.0.4 release introduced a serious bug in the RSA implementation for X86_64 CPUs supporting the AVX512IFMA instructions. This issue makes the RSA implementation with 2048 bit private keys incorrect on such machines and memory corruption will happen during the computation. As a consequence of the memory corruption an attacker may be able to trigger a remote code execution on the machine performing the computation. SSL/TLS servers or other servers using 2048 bit RSA private keys running on machines supporting AVX512IFMA instructions of the X86_64 architecture are affected by this issue. |
| A critical issue has been discovered in GitLab affecting all versions starting from 14.0 prior to 14.10.5, 15.0 prior to 15.0.4, and 15.1 prior to 15.1.1 where an authenticated user authorized to import projects could import a maliciously crafted project leading to remote code execution. |
| The GREYD.SUITE WordPress theme does not properly validate uploaded custom font packages, and does not perform any authorization or csrf checks, allowing an unauthenticated attacker to upload arbitrary files including php source files, leading to possible remote code execution (RCE). |
| USU Oracle Optimization before 5.17 allows authenticated quantum users to achieve remote code execution because of /v2/quantum/save-data-upload-big-file Java deserialization. NOTE: this is not an Oracle Corporation product. |
| A SQL injection vulnerability exists within Quest KACE Systems Management Appliance (SMA) through 12.0 that can allow for remote code execution via download_agent_installer.php. |