Search Results (120 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-32317 1 Tenda 2 Ac10, Ac10 Firmware 2025-03-17 7.5 High
Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32306 1 Tenda 2 Ac10u, Ac10u Firmware 2025-03-17 5.7 Medium
Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-30612 1 Tenda 2 Ac10u, Ac10u Firmware 2025-03-17 8.1 High
Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function.
CVE-2024-25373 1 Tenda 2 Ac10, Ac10 Firmware 2025-03-17 4.6 Medium
Tenda AC10V4.0 V16.03.10.20 was discovered to contain a stack overflow via the page parameter in the sub_49B384 function.
CVE-2023-27016 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27015 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27014 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27013 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27012 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27017 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27019 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27021 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27020 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27018 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 9.8 Critical
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2024-2581 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-22 8.8 High
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.
CVE-2023-34568 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-34566 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 9.8 Critical
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
CVE-2023-34571 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.
CVE-2023-34570 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName.
CVE-2023-34569 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.