| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. |
| A vulnerability in the “Proxy” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to manipulate the “/etc/environment” file via a crafted HTTP request. |
| A vulnerability in the “Manages app data” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to execute arbitrary client-side code in the context of another user's browser via multiple crafted HTTP requests. |
| Denial of Service in NetScaler Console (formerly NetScaler ADM), NetScaler Agent, and NetScaler SDX |
| A stack-based buffer overflow vulnerability due to a missing bounds check in the NI I/O Trace Tool may result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted nitrace file.
The NI I/O Trace tool is installed as part of the NI System Configuration utilities included with many NI software products. Refer to the NI Security Advisory for identifying the version of NI IO Trace.exe installed. The NI I/O Trace tool was also previously released as NI Spy. |
| An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. |
| Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process. |
| Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process. |
| Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process. |
| A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process. |
| A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. |
| A stack-based buffer overflow in Fortinet FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiWeb, FortiAuthenticator, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.1 through 7.0.3, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.15, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specially crafted packets. |
| The affected applications contain an out of bounds read past the end of
an allocated structure while parsing specially crafted PDF files. This
could allow an attacker to execute code in the context of the current
process. |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. |
| A stack-based buffer overflow in Fortinet FortiOS version 7.4.0 through 7.4.1 and 7.2.0 through 7.2.7 and 7.0.0 through 7.0.12 and 6.4.6 through 6.4.15 and 6.2.9 through 6.2.16 and 6.0.13 through 6.0.18 allows attacker to execute unauthorized code or commands via specially crafted CLI commands. |
| The product does not require unique and complex passwords to be created
during installation. Using Philips's default password could jeopardize
the PACS system if the password was hacked or leaked. An attacker could
gain access to the database impacting system availability and data
integrity. |
| This flaw makes curl overflow a heap based buffer in the SOCKS5 proxy
handshake.
When curl is asked to pass along the host name to the SOCKS5 proxy to allow
that to resolve the address instead of it getting done by curl itself, the
maximum length that host name can be is 255 bytes.
If the host name is detected to be longer, curl switches to local name
resolving and instead passes on the resolved address only. Due to this bug,
the local variable that means "let the host resolve the name" could get the
wrong value during a slow SOCKS5 handshake, and contrary to the intention,
copy the too long host name to the target buffer instead of copying just the
resolved address there.
The target buffer being a heap based buffer, and the host name coming from the
URL that curl has been told to operate with. |
| Versions of the package tough-cookie before 4.1.3 are vulnerable to Prototype Pollution due to improper handling of Cookies when using CookieJar in rejectPublicSuffixes=false mode. This issue arises from the manner in which the objects are initialized. |
| Insufficient Granularity of Access Control vulnerability in Drupal Paragraphs table allows Content Spoofing.This issue affects Paragraphs table: from 0.0.0 before 1.23.0, from 2.0.0 before 2.0.2. |