| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| This affects the package juce-framework/JUCE before 6.1.5. This vulnerability is triggered when a malicious archive is crafted with an entry containing a symbolic link. When extracted, the symbolic link is followed outside of the target dir allowing writing arbitrary files on the target host. In some cases, this can allow an attacker to execute arbitrary code. The vulnerable code is in the ZipFile::uncompressEntry function in juce_ZipFile.cpp and is executed when the archive is extracted upon calling uncompressTo() on a ZipFile object. |
| This affects the package codeception/codeception from 4.0.0 and before 4.1.22, before 3.1.3. The RunProcess class can be leveraged as a gadget to run arbitrary commands on a system that is deserializing user input without validation. |
| This affects all versions of package qlib. The workflow function in cli part of qlib was using an unsafe YAML load function. |
| selinux_edit_copy_tfiles in sudoedit in Sudo before 1.9.5 allows a local unprivileged user to gain file ownership and escalate privileges by replacing a temporary file with a symlink to an arbitrary file target. This affects SELinux RBAC support in permissive mode. Machines without SELinux are not vulnerable. |
| The sudoedit personality of Sudo before 1.9.5 may allow a local unprivileged user to perform arbitrary directory-existence tests by winning a sudo_edit.c race condition in replacing a user-controlled directory by a symlink to an arbitrary path. |
| A man-in-the-middle attacker can inject false responses to the client's first few queries, despite the use of SSL certificate verification and encryption. |
| An improper link resolution flaw while extracting an archive can lead to changing the access control list (ACL) of the target of the link. An attacker may provide a malicious archive to a victim user, who would trigger this flaw when trying to extract the archive. A local attacker may use this flaw to change the ACL of a file on the system and gain more privileges. |
| On all versions of Guided Configuration before 8.0.0, when a configuration that contains secure properties is created and deployed from Access Guided Configuration (AGC), secure properties are logged in restnoded logs. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated. |
| The NGINX Controller 2.0.0 thru 2.9.0 and 3.x before 3.15.0 Administrator password may be exposed in the systemd.txt file that is included in the NGINX support package. |
| An information disclosure exists in Brave Browser Desktop prior to version 1.28.62, where logged warning messages that included timestamps of connections to V2 onion domains in tor.log. |
| When curl is instructed to get content using the metalink feature, and a user name and password are used to download the metalink XML file, those same credentials are then subsequently passed on to each of the servers from which curl will download or try to download the contents from. Often contrary to the user's expectations and intentions and without telling the user it happened. |
| A vulnerability in the BIOS of Pulse Secure (PSA-Series Hardware) models PSA5000 and PSA7000 could allow an attacker to compromise BIOS firmware. This vulnerability can be exploited only as part of an attack chain. Before an attacker can compromise the BIOS, they must exploit the device. |
| The specific function of HR Portal of Soar Cloud System accepts any type of object to be deserialized. Attackers can send malicious serialized objects to execute arbitrary commands. |
| A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions) |
| Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file. |
| Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file. |
| Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file. |
| A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted. |
| Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. |