| Loftware Spectrum before 4.6 HF14 uses a Hard-coded Password. |
| NASA CryptoLib before 1.3.2 does not check the OTAR crypto function returned status, potentially leading to spacecraft hijacking. |
| Kea configuration and API directives can be used to overwrite arbitrary files, subject to permissions granted to Kea. Many common configurations run Kea as root, leave the API entry points unsecured by default, and/or place the control sockets in insecure paths.
This issue affects Kea versions 2.4.0 through 2.4.1, 2.6.0 through 2.6.2, and 2.7.0 through 2.7.8. |
| Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges |
| H3C GR1100-P v100R009 was discovered to use a hardcoded password in /etc/shadow, which allows attackers to log in as root. |
| TRENDnet TEW-814DAP v1_(FW1.01B01) was discovered to contain a hardcoded password vulnerability in /etc/shadow.sample, which allows attackers to log in as root. |
| H3C Magic R230 V100R002 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. |
| HashiCorp Consul and Consul Enterprise up to 1.11.8, 1.12.4, and 1.13.1 do not check for multiple SAN URI values in a CSR on the internal RPC endpoint, enabling leverage of privileged access to bypass service mesh intentions. Fixed in 1.11.9, 1.12.5, and 1.13.2." |
| An issue has been found in PBC through 2022-8-27. A SEGV issue detected in the function pbc_wmessage_integer in src/wmessage.c:137. |
| An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Default Credentials Cannot Be Changed. It uses a fixed default SSID and password ("qwertyuiop"), which cannot be modified by users. The SSID is continuously broadcast, allowing unauthorized access to the device network. |
| Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system. |
| Medtronic 2090 CareLink Programmer
uses a per-product username and password that is stored in a recoverable format. |
| Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest. |
| TRENDnet TEW-929DRU 1.0.0.10 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. |
| When creating an OPERATOR user account on the BMC, the redfish plugin saved the auto-generated password to /etc/fwupd/redfish.conf without proper restriction, allowing any user on the system to read the same configuration file. |
| D-Link DAP-1360 Hardcoded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DAP-1360 routers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the processing of login requests to the web-based user interface. The firmware contains hard-coded default credentials. An attacker can leverage this vulnerability to bypass authentication on the system.
. Was ZDI-CAN-18455. |
| In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the affected product stores plaintext credentials in various places. This may allow an attacker with local access to see them.
|
| Plaintext Storage of a Password vulnerability in Mia Technology Inc. MİA-MED allows Read Sensitive Strings Within an Executable.This issue affects MİA-MED: before 1.0.7.
|
| TOTOlink A3700R v9.1.2u.5822_B20200513 was discovered to contain a remote command execution (RCE) vulnerability via the setOpModeCfg function. |
| SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data. |