Search Results (43174 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2019-6588 1 Liferay 1 Liferay Portal 2024-11-21 N/A
In Liferay Portal before 7.1 CE GA4, an XSS vulnerability exists in the SimpleCaptcha API when custom code passes unsanitized input into the "url" parameter of the JSP taglib call <liferay-ui:captcha url="<%= url %>" /> or <liferay-captcha:captcha url="<%= url %>" />. Liferay Portal out-of-the-box behavior with no customizations is not vulnerable.
CVE-2019-6585 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2024-11-21 6.1 Medium
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.
CVE-2019-6577 1 Siemens 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more 2024-11-21 N/A
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
CVE-2019-6572 1 Siemens 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more 2024-11-21 9.1 Critical
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-6565 1 Moxa 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more 2024-11-21 6.1 Medium
Moxa IKS and EDS fails to properly validate user input, giving unauthenticated and authenticated attackers the ability to perform XSS attacks, which may be used to send a malicious script.
CVE-2019-6562 1 Philips 1 Tasy Emr 2024-11-21 5.4 Medium
In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
CVE-2019-6548 1 Ge 1 Ge Communicator 2024-11-21 9.8 Critical
GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
CVE-2019-6528 1 Psigridconnect 10 Iec104 Security Proxy, Iec104 Security Proxy Firmware, Smart Telecontrol Unit Tcg and 7 more 2024-11-21 8.8 High
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
CVE-2019-6504 1 Broadcom 1 Automic Workload Automation 2024-11-21 N/A
Insufficient output sanitization in the Automic Web Interface (AWI), in CA Automic Workload Automation 12.0 to 12.2, allow attackers to potentially conduct persistent cross site scripting (XSS) attacks via a crafted object.
CVE-2019-6499 1 Teradata 1 Viewpoint 2024-11-21 N/A
Teradata Viewpoint before 14.0 and 16.20.00.02-b80 contains a hardcoded password of TDv1i2e3w4 for the viewpoint database account (in viewpoint-portal\conf\server.xml) that could potentially be exploited by malicious users to compromise the affected system.
CVE-2019-6341 3 Debian, Drupal, Fedoraproject 3 Debian Linux, Drupal, Fedora 2024-11-21 N/A
In Drupal 7 versions prior to 7.65; Drupal 8.6 versions prior to 8.6.13;Drupal 8.5 versions prior to 8.5.14. Under certain circumstances the File module/subsystem allows a malicious user to upload a file that can trigger a cross-site scripting (XSS) vulnerability.
CVE-2019-6332 1 Hp 104 Deskjet 2600 4uj28b, Deskjet 2600 4uj28b Firmware, Deskjet 2600 V1n01a and 101 more 2024-11-21 4.8 Medium
A potential security vulnerability has been identified with certain HP InkJet printers. The vulnerability could be exploited to allow cross-site scripting (XSS). Affected products and versions include: HP DeskJet 2600 All-in-One Printer series model numbers 4UJ28B, V1N01A - V1N08A, Y5H60A - Y5H80A; HP DeskJet Ink Advantage 2600 All-in-One Printer series model numbers V1N02A - V1N02B, Y5Z00A - Y5Z04B; HP DeskJet Ink Advantage 5000 All-in-One Printer series model numbers M2U86A - M2U89B; HP DeskJet Ink Advantage 5200 All-in-One Printer series model numbers M2U76A - M2U78B; HP ENVY 5000 All-in-One Printer series model numbers M2U85A - M2U85B, M2U91A - M2U94B, Z4A54A - Z4A74A; HP ENVY Photo 6200 All-in-One Printer series model numbers K7G18A-K7G26B, K7S21B, Y0K13D - Y0K15A; HP ENVY Photo 7100 All-in-One Printer series model numbers 3XD89A, K7G93A-K7G99A, Z3M37A - Z3M52A; HP ENVY Photo 7800 All-in-One Printer series model numbers K7R96A, K7S00A - K7S10D, Y0G42D - Y0G52B; HP Ink Tank Wireless 410 series model numbers Z4B53A - Z4B55A, Z6Z95A - Z6Z99A, 4DX94A - 4DX95A, 4YF79A, Z7A01A; HP OfficeJet 5200 All-in-One Printer series model numbers M2U75A, M2U81A-M2U84B, Z4B12A - Z4B14A, Z4B27A - Z4B29A; HP Smart Tank Wireless 450 series model numbers Z4B56A, Z6Z96A - Z6Z98A.
CVE-2019-6324 1 Hp 20 T6b80a, T6b80a Firmware, T6b81a and 17 more 2024-11-21 N/A
HP Color LaserJet Pro M280-M281 Multifunction Printer series (before v. 20190419), HP LaserJet Pro MFP M28-M31 Printer series (before v. 20190426) may have an embedded web server potentially vulnerable to stored XSS in wireless configuration page
CVE-2019-6323 1 Hp 20 T6b80a, T6b80a Firmware, T6b81a and 17 more 2024-11-21 N/A
HP Color LaserJet Pro M280-M281 Multifunction Printer series (before v. 20190419), HP LaserJet Pro MFP M28-M31 Printer series (before v. 20190426) may have an embedded web server potentially vulnerable to reflected XSS in wireless configuration page.
CVE-2019-6278 1 Jpress 1 Jpress 2024-11-21 N/A
XSS exists in JPress v1.0.4 via Markdown input, or Markdown input with the code input option.
CVE-2019-6267 1 Premiumwpsuite 1 Easy Redirect Manager 2024-11-21 N/A
The Premium WP Suite Easy Redirect Manager plugin 28.07-17 for WordPress has XSS via a crafted GET request that is mishandled during log viewing at the templates/admin/redirect-log.php URI.
CVE-2019-6264 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.2. Inadequate escaping in mod_banners leads to a stored XSS vulnerability.
CVE-2019-6263 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.2. Inadequate checks of the Global Configuration Text Filter settings allowed stored XSS.
CVE-2019-6262 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.2. Inadequate checks of the Global Configuration helpurl settings allowed stored XSS.
CVE-2019-6261 1 Joomla 1 Joomla\! 2024-11-21 N/A
An issue was discovered in Joomla! before 3.9.2. Inadequate escaping in com_contact leads to a stored XSS vulnerability.