Search Results (41111 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-32072 1 Mitel 1 Micollab 2024-11-21 6.5 Medium
The MiCollab Client Service component in Mitel MiCollab before 9.3 could allow an attacker to get source code information (disclosing sensitive application data) due to insufficient output sanitization. A successful exploit could allow an attacker to view source code methods.
CVE-2021-32070 1 Mitel 1 Micollab 2024-11-21 5.4 Medium
The MiCollab Client Service component in Mitel MiCollab before 9.3 could allow an attacker to perform a clickjacking attack due to an insecure header response. A successful exploit could allow an attacker to modify the browser header and redirect users.
CVE-2021-32067 1 Mitel 1 Micollab 2024-11-21 6.5 Medium
The MiCollab Client Service component in Mitel MiCollab before 9.3 could allow an attacker to view sensitive system information through an HTTP response due to insufficient output sanitization.
CVE-2021-32055 2 Mutt, Neomutt 2 Mutt, Neomutt 2024-11-21 9.1 Critical
Mutt 1.11.0 through 2.0.x before 2.0.7 (and NeoMutt 2019-10-25 through 2021-05-04) has a $imap_qresync issue in which imap/util.c has an out-of-bounds read in situations where an IMAP sequence set ends with a comma. NOTE: the $imap_qresync setting for QRESYNC is not enabled by default.
CVE-2021-32040 1 Mongodb 1 Mongodb 2024-11-21 6.5 Medium
It may be possible to have an extremely long aggregation pipeline in conjunction with a specific stage/operator and cause a stack overflow due to the size of the stack frames used by that stage. If an attacker could cause such an aggregation to occur, they could maliciously crash MongoDB in a DoS attack. This vulnerability affects MongoDB Server v4.4 versions prior to and including 4.4.28, MongoDB Server v5.0 versions prior to 5.0.4 and MongoDB Server v4.2 versions prior to 4.2.16. Workaround: >= v4.2.16 users and all v4.4 users can add the --setParameter internalPipelineLengthLimit=50 instead of the default 1000 to mongod at startup to prevent a crash.
CVE-2021-32029 2 Postgresql, Redhat 5 Postgresql, Enterprise Linux, Jboss Enterprise Application Platform and 2 more 2024-11-21 6.5 Medium
A flaw was found in postgresql. Using an UPDATE ... RETURNING command on a purpose-crafted table, an authenticated database user could read arbitrary bytes of server memory. The highest threat from this vulnerability is to data confidentiality.
CVE-2021-32027 2 Postgresql, Redhat 7 Postgresql, Ansible Automation Platform, Enterprise Linux and 4 more 2024-11-21 8.8 High
A flaw was found in postgresql in versions before 13.3, before 12.7, before 11.12, before 10.17 and before 9.6.22. While modifying certain SQL array values, missing bounds checks let authenticated database users write arbitrary bytes to a wide area of server memory. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.
CVE-2021-32020 1 Amazon 1 Freertos 2024-11-21 9.8 Critical
The kernel in Amazon Web Services FreeRTOS before 10.4.3 has insufficient bounds checking during management of heap memory.
CVE-2021-31988 1 Axis 4 Axis Os, Axis Os 2016, Axis Os 2018 and 1 more 2024-11-21 8.8 High
A user controlled parameter related to SMTP test functionality is not correctly validated making it possible to add the Carriage Return and Line Feed (CRLF) control characters and include arbitrary SMTP headers in the generated test email.
CVE-2021-31987 1 Axis 4 Axis Os, Axis Os 2016, Axis Os 2018 and 1 more 2024-11-21 7.5 High
A user controlled parameter related to SMTP test functionality is not correctly validated making it possible to bypass blocked network recipients.
CVE-2021-31986 1 Axis 4 Axis Os, Axis Os 2016, Axis Os 2018 and 1 more 2024-11-21 6.8 Medium
User controlled parameters related to SMTP notifications are not correctly validated. This can lead to a buffer overflow resulting in crashes and data leakage.
CVE-2021-31977 1 Microsoft 10 Windows 10, Windows 10 1507, Windows 10 1607 and 7 more 2024-11-21 8.6 High
Windows Hyper-V Denial of Service Vulnerability
CVE-2021-31954 1 Microsoft 19 Windows 10, Windows 10 1507, Windows 10 1607 and 16 more 2024-11-21 7.8 High
Windows Common Log File System Driver Elevation of Privilege Vulnerability
CVE-2021-31893 1 Siemens 8 Simatic Pcs, Simatic Pcs Firmware, Simatic Pdm and 5 more 2024-11-21 7.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.
CVE-2021-31888 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 8.8 High
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
CVE-2021-31887 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 8.8 High
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
CVE-2021-31886 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 9.8 Critical
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
CVE-2021-31884 1 Siemens 42 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 39 more 2024-11-21 9.8 Critical
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)
CVE-2021-31875 1 Cesanta 1 Mongooseos Mjs 2024-11-21 9.8 Critical
In mjs_json.c in Cesanta MongooseOS mJS 1.26, a maliciously formed JSON string can trigger an off-by-one heap-based buffer overflow in mjs_json_parse, which can potentially lead to redirection of control flow. NOTE: the original reporter disputes the significance of this finding because "there isn’t very much of an opportunity to exploit this reliably for an information leak, so there isn’t any real security impact."
CVE-2021-31873 2 Debian, Klibc Project 2 Debian Linux, Klibc 2024-11-21 9.8 Critical
An issue was discovered in klibc before 2.0.9. Additions in the malloc() function may result in an integer overflow and a subsequent heap buffer overflow.