| The ISOinsight from Netvision has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access certain system functions. These functions include viewing the administrator list, viewing and editing IP settings, and uploading files. |
| The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication. |
| In version 0.4.1 of danswer-ai/danswer, a vulnerability exists where a basic user can create credentials and link them to an existing connector. This issue arises because the system allows an unauthenticated attacker to sign up with a basic account and perform actions that should be restricted to admin users. This can lead to excessive resource consumption, potentially resulting in a Denial of Service (DoS) and other significant issues, impacting the system's stability and security. |
| On Mercku M6a devices through 2.1.0, session tokens remain valid for at least months in some cases. |
| Lack of protection against brute force attacks in Valmet DNA visualization in DNA Operate. The possibility to make an arbitrary number of login attempts without any rate limit gives an attacker an increased chance of guessing passwords and then performing switching operations. |
| The airPASS from NetVision Information has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access the specific administrative functionality to retrieve * all accounts and passwords. |
| In WS_FTP Server versions before 8.8.9 (2022.0.9), an Incorrect Implementation of Authentication Algorithm in the Web Transfer Module allows users to skip the second-factor verification and log in with username and password only. |
| In affected versions, vulnerability-lookup did not track or limit failed
One-Time Password (OTP) attempts during Two-Factor Authentication (2FA)
verification. An attacker who already knew or guessed a valid username
and password could submit an arbitrary number of OTP codes without
causing the account to be locked or generating any specific alert for
administrators.
This lack of rate-limiting and lockout on OTP failures significantly
lowers the cost of online brute-force attacks against 2FA codes and
increases the risk of successful account takeover, especially if OTP
entropy is reduced (e.g. short numeric codes, user reuse, or predictable
tokens). Additionally, administrators had no direct visibility into
accounts experiencing repeated 2FA failures, making targeted attacks
harder to detect and investigate.
The patch introduces a persistent failed_otp_attempts counter on user
accounts, locks the user after 5 invalid OTP submissions, resets the
counter on successful verification, and surfaces failed 2FA attempts in
the admin user list. This enforces an account lockout policy for OTP
brute-force attempts and improves monitoring capabilities for suspicious
2FA activity.This issue affects Vulnerability-Lookup: before 2.18.0. |
| Statistical Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents with high-level privileges. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |
| RatPanel is a server operation and maintenance management panel. In versions 2.3.19 through 2.5.5, when an attacker obtains the backend login path of RatPanel (including but not limited to weak default paths, brute-force cracking, etc.), they can execute system commands or take over hosts managed by the panel without logging in. In addition to this remote code execution (RCE) vulnerability, the flawed code also leads to unauthorized access. RatPanel uses the CleanPath middleware provided by github.com/go-chi/chi package to clean URLs, but but the middleware does not process r.URL.Path, which can cause the paths to be misinterpreted. This is fixed in version 2.5.6. |
| CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint. |
| Aviatrix Controller versions prior to 7.1.4208, 7.2.5090, and 8.0.0 do not enforce rate limiting on password reset attempts, allowing adversaries to brute force guess the 6-digit password reset PIN |
| djangorestframework-simplejwt version 5.3.1 and before is vulnerable to information disclosure. A user can access web application resources even after their account has been disabled due to missing user validation checks via the for_user method. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| EPSON WebConfig and Epson Web Control for SEIKO EPSON Projector Products do not restrict excessive authentication attempts. An administrative user's password may be identified through a brute force attack. |
| Quest KACE Systems Management Appliance (SMA) 13.0.x before 13.0.385, 13.1.x before 13.1.81, 13.2.x before 13.2.183, 14.0.x before 14.0.341 (Patch 5), and 14.1.x before 14.1.101 (Patch 4) allows unauthenticated users to replace system licenses through a web interface intended for license renewal. Attackers can exploit this to replace valid licenses with expired or trial licenses, causing denial of service. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information. |
| A potential vulnerability was reported in the BIOS update tool driver for some Desktop, Smart Edge, Smart Office, and ThinkStation products that could allow a local user with elevated privileges to execute arbitrary code. |