Search Results (1479 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-39482 1 Softing 3 Edgeaggregator, Edgeconnector, Secure Integration Server 2025-08-12 6.5 Medium
Softing Secure Integration Server Hardcoded Cryptographic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within libopcuaclient.so. The issue results from hardcoding crytographic keys within the product. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-20610.
CVE-2021-37209 1 Siemens 54 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 51 more 2025-08-12 6.7 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.8), RUGGEDCOM i801 (All versions < V4.3.8), RUGGEDCOM i802 (All versions < V4.3.8), RUGGEDCOM i803 (All versions < V4.3.8), RUGGEDCOM M2100 (All versions < V4.3.8), RUGGEDCOM M2200 (All versions < V4.3.8), RUGGEDCOM M969 (All versions < V4.3.8), RUGGEDCOM RMC30 (All versions < V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions < V5.7.0), RUGGEDCOM RP110 (All versions < V4.3.8), RUGGEDCOM RS1600 (All versions < V4.3.8), RUGGEDCOM RS1600F (All versions < V4.3.8), RUGGEDCOM RS1600T (All versions < V4.3.8), RUGGEDCOM RS400 (All versions < V4.3.8), RUGGEDCOM RS401 (All versions < V4.3.8), RUGGEDCOM RS416 (All versions < V4.3.8), RUGGEDCOM RS416P (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions < V5.7.0), RUGGEDCOM RS8000 (All versions < V4.3.8), RUGGEDCOM RS8000A (All versions < V4.3.8), RUGGEDCOM RS8000H (All versions < V4.3.8), RUGGEDCOM RS8000T (All versions < V4.3.8), RUGGEDCOM RS900 (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900G (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900GP (All versions < V4.3.8), RUGGEDCOM RS900L (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions < V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions < V4.3.8), RUGGEDCOM RS900W (All versions < V4.3.8), RUGGEDCOM RS910 (All versions < V4.3.8), RUGGEDCOM RS910L (All versions < V4.3.8), RUGGEDCOM RS910W (All versions < V4.3.8), RUGGEDCOM RS920L (All versions < V4.3.8), RUGGEDCOM RS920W (All versions < V4.3.8), RUGGEDCOM RS930L (All versions < V4.3.8), RUGGEDCOM RS930W (All versions < V4.3.8), RUGGEDCOM RS940G (All versions < V4.3.8), RUGGEDCOM RS969 (All versions < V4.3.8), RUGGEDCOM RSG2100 (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2100P (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2200 (All versions < V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions < V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions < V5.7.0), RUGGEDCOM RSG907R (All versions < V5.7.0), RUGGEDCOM RSG908C (All versions < V5.7.0), RUGGEDCOM RSG909R (All versions < V5.7.0), RUGGEDCOM RSG910C (All versions < V5.7.0), RUGGEDCOM RSG920P V4.X (All versions < V4.3.8), RUGGEDCOM RSG920P V5.X (All versions < V5.7.0), RUGGEDCOM RSL910 (All versions < V5.7.0), RUGGEDCOM RST2228 (All versions < V5.7.0), RUGGEDCOM RST2228P (All versions < V5.7.0), RUGGEDCOM RST916C (All versions < V5.7.0), RUGGEDCOM RST916P (All versions < V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device.
CVE-2023-44318 1 Siemens 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more 2025-08-12 4.9 Medium
Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file.
CVE-2025-2810 1 Draeger 1 Icmhelper 2025-08-12 5.5 Medium
A low privileged local attacker can abuse the affected service by using a hardcoded cryptographic key.
CVE-2025-2539 1 File Away Project 1 File Away 2025-08-11 7.5 High
The File Away plugin for WordPress is vulnerable to unauthorized access of data due to a missing capability check on the ajax() function in all versions up to, and including, 3.9.9.0.1. This makes it possible for unauthenticated attackers, leveraging the use of a reversible weak algorithm, to read the contents of arbitrary files on the server, which can contain sensitive information.
CVE-2024-1040 1 Gesslergmbh 2 Web-master, Web-master Firmware 2025-08-07 4.4 Medium
Gessler GmbH WEB-MASTER user account is stored using a weak hashing algorithm. The attacker can restore the passwords by breaking the hashes stored on the device.
CVE-2025-52374 1 Hmailserver 1 Hmailserver 2025-08-07 4.6 Medium
Use of hardcoded cryptographic key in Encryption.cs in hMailServer 5.8.6 and 5.6.9-beta allows attacker to decrypt passwords to other servers from hMailAdmin.exe.config file to access other hMailServer admin consoles with configured connections.
CVE-2025-52373 1 Hmailserver 1 Hmailserver 2025-08-07 4.6 Medium
Use of hardcoded cryptographic key in BlowFish.cpp in hMailServer 5.8.6 and 5.6.9-beta allows attacker to decrypt passwords used in database connections from hMailServer.ini config file.
CVE-2024-38277 2 Fedoraproject, Moodle 2 Fedora, Moodle 2025-08-07 5.4 Medium
A unique key should be generated for a user's QR login key and their auto-login key, so the same key cannot be used interchangeably between the two.
CVE-2023-32169 2 D-link, Dlink 2 D-view, D-view 8 2025-08-07 N/A
D-Link D-View Use of Hard-coded Cryptographic Key Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the TokenUtils class. The issue results from a hard-coded cryptographic key. An attacker can leverage this vulnerability to bypass authentication on the system. . Was ZDI-CAN-19659.
CVE-2025-30477 1 Dell 1 Powerscale Onefs 2025-08-06 4.4 Medium
Dell PowerScale OneFS, versions prior to 9.11.0.0, contains a use of a broken or risky cryptographic algorithm vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
CVE-2024-5296 2 D-link, Dlink 2 D-view, D-view 8 2025-08-06 N/A
D-Link D-View Use of Hard-coded Cryptographic Key Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the TokenUtils class. The issue results from a hard-coded cryptographic key. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-21991.
CVE-2025-51726 2025-08-05 8.4 High
CyberGhostVPNSetup.exe (Windows installer) is signed using the weak cryptographic hash algorithm SHA-1, which is vulnerable to collision attacks. This allows a malicious actor to craft a fake installer with a forged SHA-1 certificate that may still be accepted by Windows signature verification mechanisms, particularly on systems without strict SmartScreen or trust policy enforcement. Additionally, the installer lacks High Entropy Address Space Layout Randomization (ASLR), as confirmed by BinSkim (BA2015 rule) and repeated WinDbg analysis. The binary consistently loads into predictable memory ranges, increasing the success rate of memory corruption exploits. These two misconfigurations, when combined, significantly lower the bar for successful supply-chain style attacks or privilege escalation through fake installers.
CVE-2025-54422 2 Sandboxie, Sandboxie-plus 2 Sandboxie, Sandboxie 2025-08-04 5.5 Medium
Sandboxie is a sandbox-based isolation software for 32-bit and 64-bit Windows NT-based operating systems. In versions 1.16.1 and below, a critical security vulnerability exists in password handling mechanisms. During encrypted sandbox creation, user passwords are transmitted via shared memory, exposing them to potential interception. The vulnerability is particularly severe during password modification operations, where both old and new passwords are passed as plaintext command-line arguments to the Imbox process without any encryption or obfuscation. This implementation flaw allows any process within the user session, including unprivileged processes, to retrieve these sensitive credentials by reading the command-line arguments, thereby bypassing standard privilege requirements and creating a significant security risk. This is fixed in version 1.16.2.
CVE-2024-20323 1 Cisco 2 Inode, Inode Manager 2025-08-01 7.5 High
A vulnerability in Cisco Intelligent Node (iNode) Software could allow an unauthenticated, remote attacker to hijack the TLS connection between Cisco iNode Manager and associated intelligent nodes and send arbitrary traffic to an affected device. This vulnerability is due to the presence of hard-coded cryptographic material. An attacker in a man-in-the-middle position between Cisco iNode Manager and associated deployed nodes could exploit this vulnerability by using the static cryptographic key to generate a trusted certificate and impersonate an affected device. A successful exploit could allow the attacker to read data that is meant for a legitimate device, modify the startup configuration of an associated node, and, consequently, cause a denial of service (DoS) condition for downstream devices that are connected to the affected node.
CVE-2024-55885 1 Beego 1 Beego 2025-08-01 7.5 High
beego is an open-source web framework for the Go programming language. Versions of beego prior to 2.3.4 use MD5 as a hashing algorithm. MD5 is no longer considered secure against well-funded opponents due to its vulnerability to collision attacks. Version 2.3.4 replaces MD5 with SHA256.
CVE-2024-10026 1 Google 1 Gvisor 2025-07-31 5.3 Medium
A weak hashing algorithm and small sizes of seeds/secrets in Google's gVisor allowed for a remote attacker to calculate a local IP address and a per-boot identifier that could aid in tracking of a device in certain circumstances.
CVE-2025-8260 1 Vaelsys 1 Vaelsys 2025-07-31 3.1 Low
A vulnerability has been found in Vaelsys 4.1.0 and classified as problematic. This vulnerability affects unknown code of the file /grid/vgrid_server.php of the component MD4 Hash Handler. The manipulation of the argument xajaxargs leads to use of weak hash. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2022-20793 1 Cisco 4 Roomos, Telepresence Ce Software, Telepresence Collaboration Endpoint and 1 more 2025-07-30 6.8 Medium
A vulnerability in pairing process of Cisco&nbsp;TelePresence CE Software and RoomOS Software for Cisco&nbsp;Touch 10 Devices could allow an unauthenticated, remote attacker to impersonate a legitimate device and pair with an affected device. This vulnerability is due to insufficient identity verification. An attacker could exploit this vulnerability by impersonating a legitimate device and responding to the pairing broadcast from an affected device. A successful exploit could allow the attacker to access the affected device while impersonating a legitimate device.There are no workarounds that address this vulnerability.
CVE-2024-20350 1 Cisco 2 Catalyst Center, Digital Network Architecture Center 2025-07-30 7.5 High
A vulnerability in the SSH server of Cisco Catalyst Center, formerly Cisco DNA Center, could allow an unauthenticated, remote attacker to impersonate a Cisco Catalyst Center appliance. This vulnerability is due to the presence of a static SSH host key. An attacker could exploit this vulnerability by performing a machine-in-the-middle attack on SSH connections, which could allow the attacker to intercept traffic between SSH clients and a Cisco Catalyst Center appliance. A successful exploit could allow the attacker to impersonate the affected appliance, inject commands into the terminal session, and steal valid user credentials.