| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Control-M/Agent is vulnerable to unauthenticated remote code execution, arbitrary file read and write and similar unauthorized actions when mutual SSL/TLS authentication is not enabled (i.e. in the default configuration).
NOTE:
* The vendor believes that this vulnerability only occurs when documented security best practices are not followed. BMC has always strongly recommended to use security best practices such as configuring SSL/TLS between Control-M Server and Agent.
* The vendor notifies that Control-M/Agent is not impacted in Control-M SaaS |
| Nautobot Single Source of Truth (SSoT) is an app for Nautobot. Prior to version 3.10.0, an unauthenticated attacker could access this page to view the Service Now public instance name e.g. companyname.service-now.com. This is considered low-value information. This does not expose the Secret, the Secret Name, or the Secret Value for the Username/Password for Service-Now.com. An unauthenticated member would not be able to change the instance name, nor set a Secret. There is not a way to gain access to other pages Nautobot through the unauthenticated Configuration page. This issue has been patched in version 3.10.0. |
| NUP Portal developed by NewType Infortech has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly upload files. If the attacker manages to bypass the file extension restrictions, they could upload a webshell and execute it on the server side. |
| A vulnerability exists in the NodeRestriction admission controller in Kubernetes clusters where node users can delete their corresponding node object by patching themselves with an OwnerReference to a cluster-scoped resource. If the OwnerReference resource does not exist or is subsequently deleted, the given node object will be deleted via garbage collection. |
| An unauthenticated remote attacker can access a URL which causes the device to reboot. |
| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |
| The paths "/cgi-bin/CliniNET.prd/utils/userlogstat.pl", "/cgi-bin/CliniNET.prd/utils/usrlogstat.pl", and "/cgi-bin/CliniNET.prd/utils/dblogstat.pl" expose data containing session IDs. |
| Unauthenticated access to the "/cgi-bin/CliniNET.prd/GetActiveSessions.pl" endpoint allows takeover of any user session logged into the system, including users with admin privileges. |
| A remote code execution vulnerability exists in multiple Netcore and Netis routers models with firmware released prior to August 2014 due to the presence of an undocumented backdoor listener on UDP port 53413. Exact version boundaries remain undocumented. An unauthenticated remote attacker can send specially crafted UDP packets to execute arbitrary commands on the affected device. This backdoor uses a hardcoded authentication mechanism and accepts shell commands post-authentication. Some device models include a non-standard implementation of the `echo` command, which may affect exploitability. |
| A vulnerability, which was classified as critical, has been found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this issue is some unknown functionality of the component API Endpoint. The manipulation leads to missing authentication. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| Authorization bypass vulnerability in Hitachi Infrastructure Analytics Advisor (Data Center Analytics component) and Hitachi Ops Center Analyzer (Hitachi Ops Center Analyzer detail view component).This issue affects Hitachi Infrastructure Analytics Advisor:; Hitachi Ops Center Analyzer: from 10.0.0-00 before 11.0.5-00. |
| Statistical Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents with high-level privileges. |
| An unauthenticated user with management network access can get and
modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20)
configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP
ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration
and execute some commands (e.g., system reboot). |
| In the Airoha Bluetooth audio SDK, there is a possible permission bypass that allows access critical data of RACE protocol through Bluetooth LE GATT service. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| Insyde IHISI function 0x49 can restore factory defaults for certain UEFI variables without further authentication by default, which could lead to a possible roll-back attack in certain platforms. This is fixed in: kernel 5.2, version 05.29.19; kernel 5.3, version 05.38.19; kernel 5.4, version 05.46.19; kernel 5.5, version 05.54.19; kernel 5.6, version 05.61.19. |
| An issue was discovered in TitanHQ SpamTitan Email Security Gateway 8.00.x before 8.00.101 and 8.01.x before 8.01.14. The file quarantine.php within the SpamTitan interface allows unauthenticated users to trigger account-level actions using a crafted GET request. Notably, when a non-existent email address is provided as part of the email parameter, SpamTitan will automatically create a user record and associate quarantine settings with it - all without requiring authentication. |
| Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected. |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| Built-in SMS-configuration command in Forever KidsWatch Call Me KW50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h and Forever KidsWatch Call Me 2 KW-60 R36CW_YDE_S4_A29_2_V1.0_2023.05.24_22.49.44_cob_b allows malicious users to change the device IMEI-number which allows for forging the identity of the device. |
| Missing Authentication - User & System Configuration |